Getting ready for Firebird 2.5 – MindTheBird

As Firebird approaches the final 2.5 release, a new campaign is born to help increase Firebird’s visibility and awareness.

Welcome MindTheBird!

MindTheBird! provides a messaging framework, marketing materials and guidance for Firebird end-users, journalists and even competitors. We encourage all developers and enthusiasts of Firebird to be the part of this very important campaign.

The MindTheBird campaign and website are coordinated by Dmitry Kuzmenko and provide free banners, presentations and email templates to help you spread the Firebird word.

Sinática is participating along with many other tools vendors and is offering free licenses to the most active Firebird Ambassadors.

Be a Firebird Ambassador yourself.

Talk about Firebird to that friend of yours who still relies on MySql. Send some links to that previous boss of yours that insisted you had to work exclusively with expensive databases. Organize a workshop to help your co-workers get started. Let your peers know Firebird is a truly free and mature database server alternative.

Comments (17)

Sinática Monitor 2.2 Beta for Firebird

A beta version of our next release is available for download.

You are welcome to test it and send your feedback.

The new features include:

  • Send alarms via email
  • Retrieve plan statements
  • Alarms for server logs

The final version along with a more descriptive release notes will be made available within the next two weeks.

Please note that this is beta software. A backup of your Sinática Monitor configuration is recommended. The files are located under the {AppData}\Sinatica\Monitor folder.

Download now!

Comments (0)

Invalid BLOB ID bug in Firebird 2.1.3

EDIT Sep 21st: Sinática Monitor 2.1.03 solves the issue. You may download it now. The original bug in Firebird 2.1.3 is already fixed in CVS too.

If you’ve followed my advice and upgraded to Firebird 2.1.3 only to find you’re now getting consistent “invalid BLOB ID” messages, please update Sinática Monitor to the latest version.

There is a very specific condition that triggers this error message and it’s highly likely you won’t be affected. If you are being affected, however, please check your environment:

  • In my testing the bug only occurs when there are clients attached using charset NONE. If you change them to use a proper charset such as ASCII, ISO8859_1 or UTF8 the error message will be gone. Any charset different from NONE will do. Also make sure Sinática Monitor is not using NONE charset.
  • If you run into this error and it’s not related to charset NONE, please contact me. Every additional information will be helpful.

A new version of Sinática Monitor is available to fix the issue.

Comments (1)

Brazilian Active Delphi Magazine – August issue

This week I received the Brazilian Active Delphi magazine with a pleasant surprise. My very first published article.

The title is Identifying performance problems with Firebird and I write about the need to evaluate performance issues before getting down to business with application and infrastructure changes.

Big thanks to Kelver Merlotti for the invitation and to all the magazine team for the opportunity.

Comments (1)

New Sinática Monitor supports Firebird 2.5

A fresh new Sinática Monitor 2.1 for Firebird is available for download.

This release supports monitoring Firebird 2.5 databases and adds new alarms and the option to choose the layout for the Charts Page.

Find out more about what’s new or check out the release notes for a complete list of changes.

Download Sinática Monitor 2.1 right now!

Comments (3)

Sinática Monitor 2.0 Final

It’s now official: Sinática Monitor 2.0 for Firebird is online.

You may download it right now and read about what’s new in the 2.0 series.

Comments (1)

Sinática Monitor 2.0 Beta

The last couple of months were intense. On one hand I wanted to fulfill the feature requests I receive, on the other hand I didn’t want to go dark for too long without a new release.

The most frequent features requests were:

  • Include filters
  • Review the History system
  • Include statement execution time
  • Reduce memory consumption

Differently from what I did in the past this time I chose a larger schedule to create a new version that would address all these requirements at once.

Thus Sinática Monitor 2.0 for Firebird SQL is born.

You may download a Beta and read about what’s new.

Don’t keep from sending me your impressions. They determine the next set of features!

Comments (1)

Improvements and fixes in Firebird 2.1.2

The Firebird Development Team released Firebird 2.1.2 this week. This sub-release focus on stability. There are no big changes, they’re all in store for Firebird 2.5, but it is important nonetheless. The list of bugs fixed is impressive.

Bugs

Among several fixes, some deserve to be highlighted:

The last two bug-fixes directly affect Sinática Monitor users. This update is highly recommended.

Improvements

Besides the fixed bugs, a few improvements were included.

  • DPB user restriction. If you connect to Firebird Server using a non-sysdba user and some special attachment parameter, check to see if it is in the restricted parameters list. It is also possible that your connectivity layer may be adding special parameter to your DPB. In these cases Firebird will reject the attachments.
  • Possible to use MS C Runtime in a private folder. In the old days (2.0 and before), all you had to do to install a client was copy fbclient.dll to you application folder or the system folder. Runtime installation then became necessary starting from Firebird 2.1. This lead to client distribution problems as client installation became more complex. Firebird 2.1.2 allows you to once again deploy a client simply by copying fbclient.dll (or gds32.dll) and the appropriate runtime files.

To know more, visit the release notes.

Download Firebird 2.1.2 now!

Comments (2)

Recommended update

Release 1.2.03 is recommended to everyone using Sinática Monitor 1.2.

This version contains important fixes to problems found in the last couple of days.

Thanks to everyone who reported errors.

View the release notes or download now.

Comments (0)

Sinática Monitor – release 1.2

Sinática Monitor release 1.2 is online now.

The most significant change in this version is the new main interface.

Containing the most important counters and a clear indication of pending alarms, the new user interface is a great quick overview of your databases’ health.

sinatica monitor main user interface

Another new feature is the Sweep Alarm. It warns you if your databases’ sweep configuration is not ideal.

You may view every improvement and fixes in the release notes.

Download Sinática Monitor 1.2 now!

Comments (0)
Next page »